USAfixTM - Repair Guide (RG) - Master Email RG
- Check the FWD/REV switch assembly
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - SWINGO 1650

Tools Required
Tool 
Torx T20
Volt meter (True RMS capable)
Wrench-Allen metric 6.0mm

Parts Required


Step Procedure & Parts & Tools
1 REMOVE 3 SCREWS FROM HANDLE COVER
Torx T20

2 REMOVE HANDLE COVER FROM THE MACHINE

3 VISUALLY INSPECT THE HANDLE MECHANICS TO MAKE SURE HALL SENSOR IS IN PLACE AND HANDLE MECHANICS ARE INSTALLED CORRECTLY (AFTER INSTALLING THE SPRING SHOULD BE VISIBLE). MOVE THE LEVERS UP AND DOWN TO CHECK COMPONENTS ARE MOVING CORRECTLY.

4 REMOVE THE WIRES FROM THE MICROSWITCH. PLACE THE LEADS WHERE THE WIRE CONNECTORS WERE. FLIP THE SWITCH AND SET THE VOLT METER TO CONTINUITY. IF THE VOLT METER BEEPS, THE MICROSWITCH IS OKAY.
Volt meter (True RMS capable)

5 REMOVE THE 5 SCREWS FROM THE CONTROL PANEL COVER.
Torx T20

6 REMOVE THE CONTROL PANEL COVER.

7 FLIP THE CONTROL PANEL OVER AND LOCATE THE HALL SENSOR PIN BLOCK (SHOWN WITH ARROW HERE).

8 REMOVE THE 2 BOLTS AT FRONT OF FRAME AND OPEN MACHINE TO LOCATE THE BATTERIES. TAKE THE VOLT METER BLACK LEAD AND CLIP TO THE NEGATIVE POST ON THE BATTERY. CLOSE THE MACHINE AND INSERT THE RED LEAD INTO PIN 2 SHOWN HERE.TURN THE KEY ON, ACTIVATE THE MACHINE, SET THE VOLT METER TO VOLTAGE. VOLT METER SHOULD READ APPROX. 5 VOLTS. IF SO, THE HALL SENSOR IS OKAY. NOTE: YOU WILL NEED A PIERCING LEAD ON VOLT METER.
Volt meter (True RMS capable)
Wrench-Allen metric 6.0mm